À-2. INTRODUCTION
The present manual is designed for those who will use the pellet burner. You
will find inside the necessary mounting, starting, maintenance and safety
data for the device.
We recommend to keep our instructions about the safety measures with a special
responsibility. Operations that require removal of elements should be executed
only by qualified and authorized specialists.The remedial actions and settings
which are not described in the manual, should not be executed.
A-3. ÎÁËÀÑÒ ÍÀ ÏÐÈËÎÆÅÍÈÅ
Ïåëåòíàòà ãîðåëêà å ïðåäíàçíà÷åíà çà èçãàðÿíå íà ïåëåòè îò äúðâåñíè
÷àñòèöè. Òÿ ñå âãðàæäà â ñïåöèàëíè êîòëè èëè â ïðåóñòðîåíè òàêèâà,
ðàáîòèëè íà äðóã òèï ãîðèâî.
A-3. APPLICATION FIELD
The pellet burner is created for burning pellets from wooden fragments. It is
installed in special boilers or adjusted ones, used to work with another type of
fuel.
A-4. ÒÅÕÍÈ×ÅÑÊÈ ÄÀÍÍÈ
· Ìîäåë: GP 20
· Ãîðèâî: ïåëåòè îò äúðâåñèíà 6-12 ìì
· Ìîùíîñò íà îòäàâàíå: 10-20 êÂò
· çà êîòëè ñ ïëîù íà ãîðåíå äî 3 ì2 (òîïëîîáìåííà ïîâúðõíèíà)
· áóíêåð çà ãîðèâîòî: íå å ÷àñò îò äîñòàâêàòà
· ïîäàâàíå íà ãîðèâîòî: âúíøåí øíåêîâ òðàíñïîðòüîð,
âêëþ÷åí â îêîìïëåêòîâêàòà íà ãîðåëêàòà
· ñëåäåíå õîäà íà ïðîöåñà íà ãîðåíå ñ ôîòî, òîïëèííè è ïîçèöèîííè
ñåíçîðè
· ñâåòëèííà ñèãíàëèçàöèÿ çà ðàáîòàòà íà ãîðåëêàòà
· óïðàâëåíèå: ìèêðîïðîöåñîðíî
· çàïàëâàíå: àâòîìàòè÷íî
· âúçìîæíîñò çà ðåãóëèðàíå íà èçõîäÿùàòà ìîùíîñò â øèðîêè
ãðàíèöè
· ñâúðçâàíå êúì åë.ìðåæàòà: 220-240 V
· òîê íà çàïàëâàíå: äî 4,5 À
· êîíñóìèðàíà ñðåäíà ìîùíîñò: ïîä 100W
· Òåãëà: · ãîðåëêà: 16 êã
· øíåêîâ òðàíñïîðòüîð: 9 êã