20
the burner turns off. The fan stays turned on for about 5 min. (parameter
Ò5, set by the manufacturer) so that the pellets in the burner’s head will
burn out. After the temperature falls and follows starting-signal from the
thermostat, the burner turns on again.
· If during work the set temperature goes down, the burner will turn off.
· If during rest when a set temperature is being increased, then the burner
will turn on.
· If the pellets don’t ignite, a new attempt for their burning will start
automatically.
· If the sensor does not detect any flame during work, the ignite algorithm
will start again.
· If more than few attempts for ignition appear unsuccessful, for example
if the fuel ends (parameter C1, set at two attempts), then the device
turns off the normal algorithm and a mode ALARM will start – a lamp
ALARM will light constantly which is a signal for the user that the
reason should be removed. After removing the disturbance in the normal
work, the burner starts again with its turning off and. This may be done
by the switcher POWER placed on the burner’s cover (it stops the
feeding for the logical module into the burner and clears the alarm) or
by turning off the common boiler feeding through its main circuit-breaker.
· When the electrical supply stops and then restores, the burner starts
automatic.
TURNING THE BURNER OFF. IMPORTANT! If during work you wish to turn off
the burner, this must be done in the following way: first decrease the set
temperature from the boiler thermostat through its turning in starting
position. After 5 minutes (time enough for the combustion of the pellets in the
burner), the burner turns off through its switch and the boiler respectively through
its main switch. ATTENTION, if the above sequence is not kept, the pellets burn
out without burner fan turned on (it is possible overheating and break-down of the
photosensor).
D- ÎÏÈÑÀÍÈÅ ÍÀ ÊÎÍÑÒÐÓÊÖÈßÒÀ
D. DESCRIPTION OF THE CONSTRUCTION
D-1. ÎÑÍÎÂÍÈ ÂÚÇËÈ È ÌÅÕÀÍÈÇÌÈ
Îáùèÿ âèä íà ãîðåëêàòà ñúñ çàõðàíâàùèÿ øíåê ñà ïîêàçàíè íà ôèã D1.
Êîìïëåêòúò ñå ñúñòîè îñíîâíî îò ñëåäíèòå ñúñòàâíè ÷àñòè:
· Ãîðåëêà
· Øíåê